Product description
Extra Long Blue Nitrile Gloves 30cm. Powder-free, model GD30 in blue. They are thin and sensitive. The surface of the glove is treated with chlorine, preventing the gloves from sticking together as can happen with gloves from other brands. In addition, being made of nitrile, they improve the protection of gloves with micro holes of some conventional latex gloves.
- Antimicrobial Protection
- Hand Protection
- Chemical Resistance
- Medical Protection
- Slip Resistant
Request a free sample
Test first and buy later. Visit any product page to request your free sample.
Standards and labels
EN 16523-1:2015 is a European standard that defines the performance requirements and test methods for automatic towel dispensers. It sets guidelines for how much towel should come out, how high the nozzle should be, and how hard it should be to activate the dispenser. The test results should show that the dispenser meets these guidelines.
Test results
Permeation Contact TestedEN 16523-1:2015 provides the methodology for determining the resistance of materials used in protective clothing to permeation by chemicals under continuous contact. The designation 'Tested' signifies that the material has been evaluated for its ability to prevent chemical penetration over a specified duration and under certain conditions. The test method involves placing the test chemical in contact with the material and measuring the rate at which the chemical passes through to the other side, simulating exposure scenarios where chemicals might come into continuous contact with the protective gear. Materials that have undergone this testing are crucial for industries such as chemical manufacturing, healthcare, and laboratory work, where workers are exposed to hazardous substances. This certification ensures that the protective clothing provides a reliable barrier against chemical risks, enhancing safety and compliance with health and safety regulations.
EN 374-1:1995 is a standard that specifies the performance requirements and test methods for chemical protective gloves. It defines the minimum requirements for gloves to protect against chemicals and microorganisms. The standard includes test methods for permeation resistance, degradation, and penetration. Possible test results include pass/fail for each requirement.
EN 374-5:2016 is a European standard for gloves that protect against microorganisms, specifically gloves that are used for medical and dental procedures. It sets rules for how the gloves should protect against microorganisms and how to test if they meet the standards. Gloves that pass the tests can have a label that says they meet the standard. The test results can be pass or fail for each test that checks the gloves resistance to microorganisms.
Test results
Micro-organisms VirusEN 374-5:2016 is a standard that outlines the requirements and testing methods for protective gloves designed to protect against viruses. The designation 'Virus' indicates that the gloves have passed specific tests confirming their barrier effectiveness against viruses. These tests involve assessing the glove material's resistance to penetration by blood-borne pathogens and other virus-containing fluids, using a bacteriophage as a surrogate virus due to its small size and resistance. Gloves that meet this standard are vital in healthcare settings, laboratories, and any environment where there is a risk of exposure to viral infections. They are crucial for preventing the transmission of diseases, ensuring that workers are protected when handling potentially infectious materials, thus enhancing safety and health protocols in workplaces with biological hazards.
Micro-organisms Bacteria & FungiEN 374-5:2016 specifies the requirements and test methods for protective gloves intended to protect against bacteria and fungi. The designation 'Bacteria & Fungi' indicates that the gloves have been tested and verified to provide effective barrier protection against microbial agents. The testing involves evaluating the glove's material and seams for their impermeability to microorganisms under conditions that simulate real-world use, ensuring no penetration occurs through the glove material or at the seams. Gloves certified under this standard are crucial for use in environments such as healthcare, laboratory settings, and any applications where preventing the transmission of infectious agents is essential. They help ensure the safety and hygiene of workers by providing reliable protection against the risks of bacterial and fungal contamination.
EN 455-3:2015 is a European standard for disposable medical gloves. It sets out the definition, performance requirements and test methods for this type of gloves. The standard includes requirements for physical properties, dimensions, packaging, freedom from holes, freedom from powder, freedom from protein, freedom from endotoxins and freedom from pyrogens. Test results can include measurements of the gloves' physical properties, dimensions, packaging, freedom from holes, freedom from powder, freedom from protein, freedom from endotoxins and freedom from pyrogens. This version of the standard includes some changes and updates from the 2006 version.
EN 455-2:2015 is a European standard for disposable medical gloves. It sets out the definition, performance requirements and test methods for this type of gloves. The standard includes requirements for physical properties, dimensions, packaging, freedom from holes, freedom from powder, freedom from protein, freedom from endotoxins, and freedom from pyrogens. Test results can include measurements of the gloves' physical properties, dimensions, packaging, freedom from holes, freedom from powder, freedom from protein, freedom from endotoxins, and freedom from pyrogens. This version of the standard includes some changes and updates from the 2009 version.
Test results
Physical Properties TestedThe EN 455-2:2015 standard pertains to the physical properties of medical gloves, primarily focusing on ensuring they meet required levels of durability and performance under typical usage conditions. The designation that the physical properties were Tested under this standard implies that the gloves have undergone specific testing protocols to measure their tensile strength and elasticity and have been found compliant with predefined standards. The test method for physical properties under EN 455-2:2015 involves simulating conditions to mimic normal use and stresses that gloves would experience, such as stretching, which reveals both the elasticity and tensile strength of the material. Gloves undergoing these tests are stretched until they can stretch no further without breaking, and these results indicate whether the gloves are suitable for practical use in medical environments, offering users confidence in the durability and integrity of the gloves under operational conditions.
EN 455-1:2020 is a European standard for disposable medical gloves. It sets out the definition, performance requirements and test methods for this type of gloves. The standard includes requirements for freedom from holes, tensile strength, elongation, packaging, freedom from powder, freedom from protein, freedom from endotoxins, and freedom from pyrogens. Test results can include measurements of the gloves' freedom from holes, tensile strength, elongation, packaging, freedom from powder, freedom from protein, freedom from endotoxins and freedom from pyrogens. This version of the standard includes some changes and updates from the 2000 version.
Test results
Tightness AQL #,##EN 455-1:2020 sets the standards for medical gloves for single use, focusing on freedom from holes and ensuring glove integrity. The 'Tightness' test result, indicated by an Acceptable Quality Level (AQL) value, measures the quality level acceptable for the pinhole rate in glove batches. A lower AQL value, such as 1.5, typically used in medical settings, signifies a higher level of quality control where fewer gloves with defects are allowed. The testing for this standard involves randomly selecting gloves from a batch and filling them with water to check for leaks. Gloves that pass this test at a certain AQL value are deemed safe for use in medical and surgical procedures, where maintaining a sterile environment is crucial to prevent contamination and infection. This certification ensures that users can rely on the protective barrier of the gloves against pathogens and other contaminants.
EN 1186 is a European standard that specifies requirements and test methods for the safety of materials and articles that come into contact with food. The standard provides a framework for evaluating the safety of food contact materials by establishing guidelines for testing their chemical compatibility with food and determining the potential for migration of harmful substances into food. EN 1186 is divided into several parts, each of which addresses a different aspect of food contact materials. EN 1186-7: Test Methods for Overall Migration into Fatty Food Simulants - This part specifies test methods for determining the overall migration of substances from food contact materials into fatty food simulants.
Test results
General Requirements GuideEN ISO 21420:2020 is a standard that outlines general requirements and guidelines for protective gloves, aiming to ensure their quality, performance, and suitability for various applications. When a product meets the requirements outlined in the General Requirements section of EN ISO 21420:2020, it signifies that the gloves comply with fundamental quality and performance criteria, including factors such as size, fit, ergonomics, and dexterity. The practical implications of this compliance are significant, as it assures users of the gloves' basic functionality and suitability for general hand protection purposes across a range of industries and applications. The test method involves evaluating various aspects of the gloves, including dimensions, construction, materials, and labeling, to ensure conformity with the specified requirements. Compliance with these general requirements enhances user confidence in the protective gloves' reliability and effectiveness, promoting workplace safety and facilitating compliance with regulatory standards.
EN 13485:2016 is a standard for a Quality Management System for Medical Devices. It sets out the requirements for a quality management system where an organization needs to demonstrate its ability to provide medical devices and related services that consistently meet customer and regulatory requirements. This standard is used to demonstrate a company's ability to meet specific quality and safety requirements for the design, production, installation and servicing of medical devices. Test results can include audits and inspections of the organization's facilities, processes, and products to ensure compliance with the standard.
CE Marking is a label that shows a product meets certain safety and environmental standards set by the European Union. To get the CE Marking, a company must test and certify their product meets these standards. CE Marking is required for many products sold in the EU, including electronics, machinery, toys and medical devices. It helps ensure that products are safe for consumers and the environment, and allows for easy trade within the EU.
Food safe refers to the safety of food products that are used or consumed by people. In Europe, food safety is regulated by the European Union (EU) and the European Food Safety Authority (EFSA). These organizations set standards and requirements for food products to ensure they are safe to eat. To be considered "food safe" in Europe, a product must meet these standards and be free of harmful substances. This includes being free of harmful bacteria, pesticides, and other contaminants. Food products that do not meet these standards cannot be sold or used in the EU.
MD stands for "Medical Device." It refers to any instruments, apparatus, machines, implants, or other similar or related articles that are intended to be used for human beings for the purpose of diagnosis, prevention, monitoring, treatment or alleviation of disease, injury or disability. In Europe, a MD Label is a special label that must be on all Medical Devices that are sold or used in the European Union (EU). The label must include information about the product, such as the name of the manufacturer, the intended use of the product and CE mark. To be able to sell or use a Medical Device in the EU, the device must meet certain standards and requirements set by the European Union and notified body.
PPE stands for "personal protective equipment." PPE Category 3 refers to equipment that is complex and provide the highest level of protection such as powered respirators, SCBA, and full body suits. In Europe, PPE Category 3 must meet certain safety standards set by the European Union, which means that it must be designed and manufactured to protect the user without causing harm. Companies that make or sell PPE must prove that it meets these standards. They also must have a quality management system in place, have to be audited regularly by a notified body and have to have a technical documentation.
Santex delivery terms
Free delivery for all Santex products
Santex GD30 Extra Long Nitrile Gloves, Blue, 100 pcs
71,40 € / carton (VAT incl.)
60,00 €
carton VAT 0%
A carton contains 10 packages (1 000 pcs)
6,00 € / 100 pcs
48 cartons / 48 000 pcs:
4,32 € / 100 pcs
In a package
100 pieces
In a carton
10 packages
1 000 pieces
On a pallet
48 cartons
48 000 piece
Santex
Delivery time: 10 business days
Orders from 1 500,00 €
Free delivery for all Santex products
Find +150,000 products from hundreds of brands
Autonomous sourcing platform
The most efficient way to source and order supplies for your operations
Sourcing
Ordering
Recommended products
List products you’re looking for and we’ll find the best products and prices for you – all for free.
Customer service / ---