Meditrade Nitril® Sensory® White Nitrile Examination Glove, Powder-Free
Product description
The product description has not been specified
Indicates the glove's pigmentation, which can aid in color-coding tasks, enhancing visibility, or meeting specific industry requirements for contamination control.
Refers to whether gloves have a smooth or textured finish, affecting grip strength, dexterity, and handling ability in wet or dry conditions.
Indicates whether gloves contain donning powder. Powder-free options reduce allergen risks and contamination, while powdered versions offer easier application.
Crafted without natural rubber latex, these gloves are ideal for sensitive skin. Provides a comfortable fit for those with latex sensitivities.
Surface is treated for effortless donning and a smooth feel. Reduces tackiness and minimizes latex allergens for enhanced comfort and usability.
Designed for use on either hand, these gloves offer convenience and efficiency. Their symmetrical design simplifies donning and reduces waste.
Offers complete hand coverage, ensuring hygiene and protection. Ideal for various tasks requiring a barrier against contamination and maintaining cleanliness.
Offers versatile hand protection for various tasks. Balances durability and flexibility, suitable for diverse applications requiring barrier protection.
Describes whether fingertips have a smooth or textured surface, affecting grip strength, tactile sensitivity, and handling precision for various applications.
- Medical Protection
- Antimicrobial Protection
- Hand Protection
Request a free sample
Test first and buy later. Visit any product page to request your free sample.
Standards and labels
EN 455-2:2015 is a European standard for disposable medical gloves. It sets out the definition, performance requirements and test methods for this type of gloves. The standard includes requirements for physical properties, dimensions, packaging, freedom from holes, freedom from powder, freedom from protein, freedom from endotoxins, and freedom from pyrogens. Test results can include measurements of the gloves' physical properties, dimensions, packaging, freedom from holes, freedom from powder, freedom from protein, freedom from endotoxins, and freedom from pyrogens. This version of the standard includes some changes and updates from the 2009 version.
Test results
Physical Properties TestedThe EN 455-2:2015 standard pertains to the physical properties of medical gloves, primarily focusing on ensuring they meet required levels of durability and performance under typical usage conditions. The designation that the physical properties were Tested under this standard implies that the gloves have undergone specific testing protocols to measure their tensile strength and elasticity and have been found compliant with predefined standards. The test method for physical properties under EN 455-2:2015 involves simulating conditions to mimic normal use and stresses that gloves would experience, such as stretching, which reveals both the elasticity and tensile strength of the material. Gloves undergoing these tests are stretched until they can stretch no further without breaking, and these results indicate whether the gloves are suitable for practical use in medical environments, offering users confidence in the durability and integrity of the gloves under operational conditions.
EN ISO 13485:2016 is a standard for quality management systems for medical devices. It sets guidelines for design and development, production, installation and servicing of medical devices. Test results include measurements of compliance with the standard's requirements. It also includes guidelines for continual improvement, risk management and regulatory compliance. This is a specific version of the standard, updated from the 2012 version.
EN 455-4:2009 is a European standard for disposable medical gloves. It sets out the definition, performance requirements and test methods for this type of gloves. The standard includes requirements for freedom from holes, dimensions, packaging, freedom from powder, freedom from protein and freedom from endotoxins. Test results can include measurements of the gloves' freedom from holes, dimensions, packaging, freedom from powder, freedom from protein and freedom from endotoxins.
EN 455-1:2020 is a European standard for disposable medical gloves. It sets out the definition, performance requirements and test methods for this type of gloves. The standard includes requirements for freedom from holes, tensile strength, elongation, packaging, freedom from powder, freedom from protein, freedom from endotoxins, and freedom from pyrogens. Test results can include measurements of the gloves' freedom from holes, tensile strength, elongation, packaging, freedom from powder, freedom from protein, freedom from endotoxins and freedom from pyrogens. This version of the standard includes some changes and updates from the 2000 version.
Test results
Tightness AQL #,##EN 455-1:2020 sets the standards for medical gloves for single use, focusing on freedom from holes and ensuring glove integrity. The 'Tightness' test result, indicated by an Acceptable Quality Level (AQL) value, measures the quality level acceptable for the pinhole rate in glove batches. A lower AQL value, such as 1.5, typically used in medical settings, signifies a higher level of quality control where fewer gloves with defects are allowed. The testing for this standard involves randomly selecting gloves from a batch and filling them with water to check for leaks. Gloves that pass this test at a certain AQL value are deemed safe for use in medical and surgical procedures, where maintaining a sterile environment is crucial to prevent contamination and infection. This certification ensures that users can rely on the protective barrier of the gloves against pathogens and other contaminants.
EN 374-4:2013 is a European standard for gloves that protect against microorganisms. It sets rules for how the gloves should protect against microorganisms and how to test if they meet the standards. Gloves that pass the tests can have a label that says they meet the standard. The test results can be pass or fail for each test that checks the gloves resistance to microorganisms.
Test results
Degradation TestedThe standard EN 374-4:2013 pertains to the determination of degradation by chemicals for protective gloves. Degradation is assessed based on the change in physical properties of the glove material after contact with a chemical. Specifically, a result indicating degradation provides a measure of the glove's deterioration in terms of features like tensile strength and elongation when exposed to specific chemicals, gauged through physical tests such as elongation and tensile tests. The test method involves exposing the glove material to the chemical over a determined period, followed by mechanical testing to compare the pre and post-exposure properties. This result is crucial in determining the glove's suitability for use with specific chemicals, as degradation can significantly reduce its protective effectiveness, potentially endangering the user. Hence, understanding and adhering to this standard helps in the selection of appropriate protective gloves for specific chemical exposure scenarios, ensuring user safety and compliance with health and safety regulations.
EN 374-1:2005 is a European standard that specifies the performance requirements and test methods for chemical protective gloves. It defines the minimum requirements for gloves that protect against chemicals and microorganisms. The standard includes tests for permeation resistance, degradation, and penetration. Possible test results include pass/fail for each requirement.
Test results
General Requirements Type CEN 374-1:2005 also details general requirements, where Type C indicates basic chemical resistance. These gloves are tested against a limited number of chemicals and must meet minimal performance requirements. Type C gloves are intended for low-risk exposure scenarios where only light chemical contact is expected, such as in certain laboratory tasks or during routine cleaning operations where harsh chemicals are not used extensively.
EN 374-5:2016 is a European standard for gloves that protect against microorganisms, specifically gloves that are used for medical and dental procedures. It sets rules for how the gloves should protect against microorganisms and how to test if they meet the standards. Gloves that pass the tests can have a label that says they meet the standard. The test results can be pass or fail for each test that checks the gloves resistance to microorganisms.
Test results
Micro-organisms Bacteria & FungiEN 374-5:2016 specifies the requirements and test methods for protective gloves intended to protect against bacteria and fungi. The designation 'Bacteria & Fungi' indicates that the gloves have been tested and verified to provide effective barrier protection against microbial agents. The testing involves evaluating the glove's material and seams for their impermeability to microorganisms under conditions that simulate real-world use, ensuring no penetration occurs through the glove material or at the seams. Gloves certified under this standard are crucial for use in environments such as healthcare, laboratory settings, and any applications where preventing the transmission of infectious agents is essential. They help ensure the safety and hygiene of workers by providing reliable protection against the risks of bacterial and fungal contamination.
EN 374-2:2014 is a European standard that defines the performance requirements and test methods for chemical protective gloves against microorganisms. It specifies the minimum requirements for gloves to protect against microorganisms. The standard includes test methods for resistance to penetration by microorganisms and possible test results include pass/fail for each requirement.
Test results
Penetration Resistance TestedEN 374-2:2014 is an European Standard that specifies the requirements and test methods for evaluating the resistance of gloves to penetration by chemicals and/or microorganisms. In the test a glove is assessed for its capacity to resist penetration by micro-organisms or chemicals through pores, pinholes, or other imperfections. The test method involves inflating the glove with air or filling it with water and then examining it for leaks. This standard is important for ensuring that protective gloves do not allow harmful substances to reach the skin, thereby providing safety in chemical and biological environments.
EN 16523-1:2015 is a European standard that defines the performance requirements and test methods for automatic towel dispensers. It sets guidelines for how much towel should come out, how high the nozzle should be, and how hard it should be to activate the dispenser. The test results should show that the dispenser meets these guidelines.
Test results
Permeation Contact TestedEN 16523-1:2015 provides the methodology for determining the resistance of materials used in protective clothing to permeation by chemicals under continuous contact. The designation 'Tested' signifies that the material has been evaluated for its ability to prevent chemical penetration over a specified duration and under certain conditions. The test method involves placing the test chemical in contact with the material and measuring the rate at which the chemical passes through to the other side, simulating exposure scenarios where chemicals might come into continuous contact with the protective gear. Materials that have undergone this testing are crucial for industries such as chemical manufacturing, healthcare, and laboratory work, where workers are exposed to hazardous substances. This certification ensures that the protective clothing provides a reliable barrier against chemical risks, enhancing safety and compliance with health and safety regulations.
EN 455-3:2015 is a European standard for disposable medical gloves. It sets out the definition, performance requirements and test methods for this type of gloves. The standard includes requirements for physical properties, dimensions, packaging, freedom from holes, freedom from powder, freedom from protein, freedom from endotoxins and freedom from pyrogens. Test results can include measurements of the gloves' physical properties, dimensions, packaging, freedom from holes, freedom from powder, freedom from protein, freedom from endotoxins and freedom from pyrogens. This version of the standard includes some changes and updates from the 2006 version.
Meditrade delivery terms
Free delivery for all Meditrade products
64,65 €
Price per 10 packages (2 000 pcs)
3,23 € / 100 pcs
Other products you may like
Similar products you may like
Recommended for you
Meditrade
Delivery time: 3 business days
Orders from 50,00 €
Supplier shipping fee 5,00 €
Free shipping on orders over 150,00 €



Find +150,000 products from hundreds of brands
Autonomous sourcing platform
The most efficient way to source and order supplies for your operations
Sourcing
Ordering
List products you’re looking for and we’ll find the best products and prices for you – all for free.
--- / Customer service