Product description
The Jokasafe JokaNordic cold-resistant vinyl glove is a JokaXo work glove with a removable artificial fur liner.
The durable double vinyl 360° coating remains flexible in -50°C frost. Smooth TopGrip® surface provides a firm grip in dry, wet and oily conditions.
EN ISO 4675:2017, EN ISO 7854:1997 Method A, EN ISO 2286-3:1998. CE and REACH approved.
- Cut Resistant
- Machine Washable
Request a free sample
Test first and buy later. Visit any product page to request your free sample.
Standards and labels
EN ISO 374-1:2016 is a standard that defines the performance requirements for gloves that protect against chemicals and microorganisms. The standard specifies the design, materials, and testing requirements for gloves to protect against chemicals and microorganisms. Possible test results include measurements of the gloves' permeation resistance, degradation, and penetration. It also includes the safety and functionality requirements for gloves.
Test results
Specified Requirements Type AEN 388:2016 is a European standard for measuring the performance of protective gloves against mechanical risks (abrasion, cut, tear, and puncture). The standard includes test methods and performance requirements for gloves to be considered compliant. Test results are reported using a series of four numbers, each representing the performance level achieved in one of the tests.
Test results
Puncture Resistance Level 1The European standard EN 388:2016 addresses the puncture resistance of protective gloves, with puncture resistance classified from Levels 1 to 4. Specifically, a Level 1 result indicates minimal puncture resistance. This level of resistance is determined by a test involving a standardized stylus with a specified diameter and force. During the test, the stylus is pressed against the material with a force up to 20 Newtons to assess how well the glove can withstand penetration. A Level 1 rating signifies that the glove provides basic protection against small punctures or stabs, appropriate for areas with minimal risk. Practical implications for this test result suggest the gloves are suitable for light tasks where major risks of punctures are not anticipated, but are not adequate for handling sharp tools or heavy equipment where higher penetration resistance would be necessary.
Tear Resistance Level 2EN 388:2016 is a European standard that sets criteria for testing the mechanical risks for protective gloves, including abrasion, cut, tear, and puncture resistance. The Tear Resistance Level 2 designation indicates that the gloves have a moderate level of resistance to tearing. The test for tear resistance involves subjecting a sample of the glove material to a force until it tears, and the force required to initiate and propagate the tear is measured. Gloves that achieve Level 2 tear resistance can withstand between 25 to 50 Newtons of force. This level of tear resistance is suitable for tasks where gloves might face moderate stresses that could cause tearing, such as general handling and light industrial work where sharp or jagged materials are handled less frequently. These gloves provide reliable protection and durability in scenarios where some degree of mechanical risk is present but not excessively severe.
Cut Resistance, ISO 13997 Level XThe standard EN 388:2016, specifically its segment referring to ISO 13997 test, is designed to assess the cut resistance of materials used in protective gloves. A result denoted as 'Level X' means that test is not performed and the cut resistance of the product cannot be guaranteed.
Abrasion Resistance Level 2EN 388:2016 is an updated European standard that specifies criteria for testing gloves to protect against mechanical risks, including abrasion, cuts, tears, and puncture. The Abrasion Resistance Level 2 classification within this standard indicates a moderate level of protection against wear from rough materials. The abrasion resistance test involves subjecting the glove material to repeated cycles of sandpaper under pressure until the material wears through. Level 2 abrasion resistance means the gloves can withstand between 500 to 1999 cycles before being penetrated. This level of protection is suitable for tasks that involve handling or coming into contact with abrasive materials but not at an extreme or heavy-duty level. Gloves with Level 2 abrasion resistance are well-suited for general handling tasks, offering durability and protection to extend the life of the glove while maintaining good dexterity and comfort.
Cut Resistance, Coup Test Level 1The EN 388:2016 standard is dedicated to gauging the mechanical risks for hand protection where a Cut Resistance, Coup Test Level 1 indicates minimal resistance to cutting because material achieved between 1.2 and 2.5 cycles before being cut through during the test. It means that the product tested at this level offers basic protection against shallow cuts, suitable for tasks with low risk of cut injuries. The test method used involves a rotating circular blade under a fixed force making contact with the fabric or material being tested. The blade moves back and forth across the material until a cut-through is achieved. The number of cycles required to cut through the sample at a consistent speed determines the cut resistance, with Level 1 being the second lowest rating after level 0. Products at this level are applicable in scenarios where there are minimal hazards from sharp objects, hence ideal for light duties where there is no significant risk of deep cuts.
EN ISO 2286-3:1998 is a standard that sets the requirements for the performance and testing of cosmetics. The standard defines the requirements for materials, design, and test methods for cosmetics, to ensure that they are safe to use and provide good performance. Test results will include information on product pH, viscosity, stability, and compatibility with the skin. The standard is intended to ensure that cosmetics are safe to use and provide good performance. This standard covers the general rules for preservatives effectiveness testing of cosmetics.
EN ISO 7854:1997 is a standard for testing the flammability of automotive interior materials. It specifies the method for measuring the burning behavior of materials used in car interiors such as seats, dashboard, door panels, and headliners in a vertical position. The performance requirements include how quickly the material burns, how much it continues to burn after the flame is removed, and how much smoke is produced. Possible test results include a flame spread index, after flame index, smoke density, and toxic gas emissions. These test results are used to evaluate the flammability of the materials used in car interiors and to classify it according to the standard's criteria.
EN 16523-1:2015 is a European standard that defines the performance requirements and test methods for automatic towel dispensers. It sets guidelines for how much towel should come out, how high the nozzle should be, and how hard it should be to activate the dispenser. The test results should show that the dispenser meets these guidelines.
Test results
Permeation Contact TestedEN 16523-1:2015 provides the methodology for determining the resistance of materials used in protective clothing to permeation by chemicals under continuous contact. The designation 'Tested' signifies that the material has been evaluated for its ability to prevent chemical penetration over a specified duration and under certain conditions. The test method involves placing the test chemical in contact with the material and measuring the rate at which the chemical passes through to the other side, simulating exposure scenarios where chemicals might come into continuous contact with the protective gear. Materials that have undergone this testing are crucial for industries such as chemical manufacturing, healthcare, and laboratory work, where workers are exposed to hazardous substances. This certification ensures that the protective clothing provides a reliable barrier against chemical risks, enhancing safety and compliance with health and safety regulations.
EN 374-5:2016 is a European standard for gloves that protect against microorganisms, specifically gloves that are used for medical and dental procedures. It sets rules for how the gloves should protect against microorganisms and how to test if they meet the standards. Gloves that pass the tests can have a label that says they meet the standard. The test results can be pass or fail for each test that checks the gloves resistance to microorganisms.
Test results
Micro-organisms VirusEN 374-5:2016 is a standard that outlines the requirements and testing methods for protective gloves designed to protect against viruses. The designation 'Virus' indicates that the gloves have passed specific tests confirming their barrier effectiveness against viruses. These tests involve assessing the glove material's resistance to penetration by blood-borne pathogens and other virus-containing fluids, using a bacteriophage as a surrogate virus due to its small size and resistance. Gloves that meet this standard are vital in healthcare settings, laboratories, and any environment where there is a risk of exposure to viral infections. They are crucial for preventing the transmission of diseases, ensuring that workers are protected when handling potentially infectious materials, thus enhancing safety and health protocols in workplaces with biological hazards.
Micro-organisms Bacteria & FungiEN 374-5:2016 specifies the requirements and test methods for protective gloves intended to protect against bacteria and fungi. The designation 'Bacteria & Fungi' indicates that the gloves have been tested and verified to provide effective barrier protection against microbial agents. The testing involves evaluating the glove's material and seams for their impermeability to microorganisms under conditions that simulate real-world use, ensuring no penetration occurs through the glove material or at the seams. Gloves certified under this standard are crucial for use in environments such as healthcare, laboratory settings, and any applications where preventing the transmission of infectious agents is essential. They help ensure the safety and hygiene of workers by providing reliable protection against the risks of bacterial and fungal contamination.
EN 511:2006 is a European standard that sets requirements for the protection against cold for gloves and mittens. It covers factors such as resistance to cold, water penetration and breathability. Testing must be done by a certified lab and must show that the product meets all requirements of the standard. Possible test results would include pass/fail for each requirement, as well as specific measurement data.
Test results
Cold Contact Level 2The standard EN 511:2006 specifies requirements for protective gloves that guard against cold environments. Cold Contact result Level 2 indicates moderate insulation against contact cold, quantified with a thermal resistance measurement in the range of 0.050 to less than 0.100 m²°C/W. This means gloves achieving this level can provide a reasonable amount of insulation, helping to reduce heat transfer from the hands to the cold contact surface, thereby lowering the rate at which hands become cold. The measurement of contact cold resistance is performed using a standardized test that involves placing the glove materials against metal plates cooled to different temperatures. The difference in temperature across the glove material is then analyzed to determine its thermal resistance. For practical implications, gloves classified under Level 2 of Cold Contact in EN 511:2006 are suitable for environments or tasks where individuals are exposed to cold objects but do not necessarily involve extreme cold or extended exposure, offering a balance between dexterity and protection from the cold .
Convective Cold Level 3EN 511:2006 is a European standard that assesses the protective qualities of gloves against cold. The Convective Cold result Level 3 represents a performance level where gloves have a thermal resistance of 0.22 m²°C/W but less than 0.30 m²°C/W. This specification indicates that these gloves can effectively insulate against cold due to convective air movements at a significant level but not at the highest possible level. The test involves placing a heated hand form within the glove and monitoring the power required to maintain a constant temperature while the surrounding air temperature is progressively lowered. The thermal resistance (ITR) measured in these conditions reflects how well the glove can keep heat from being lost through convection, which is crucial for users in environments where exposure to cold air might otherwise decrease hand dexterity and comfort, affecting work performance and safety .
Water Tightness Level 1EN 511:2006 is a European standard focused on testing the water tightness of protective gloves against penetration by water. Its purpose is to ensure that protective gloves offer adequate resistance to water. A Level 1 rating in water tightness signifies that the gloves provide basic protection against water penetration, though they may not be suitable for prolonged exposure to wet conditions. The test method involves placing the gloves on a hand-shaped form, filling them with water, and then observing for any signs of leakage over a specified period. Practical implications of this result for the product category include indicating that the gloves offer some degree of protection against water exposure, making them suitable for use in mildly wet or cold environments where only limited exposure to water is expected. However, they may not be suitable for prolonged exposure to heavy rainfall or immersion in water.
EN 374-2:2014 is a European standard that defines the performance requirements and test methods for chemical protective gloves against microorganisms. It specifies the minimum requirements for gloves to protect against microorganisms. The standard includes test methods for resistance to penetration by microorganisms and possible test results include pass/fail for each requirement.
Test results
Penetration Resistance TestedEN 374-2:2014 is an European Standard that specifies the requirements and test methods for evaluating the resistance of gloves to penetration by chemicals and/or microorganisms. In the test a glove is assessed for its capacity to resist penetration by micro-organisms or chemicals through pores, pinholes, or other imperfections. The test method involves inflating the glove with air or filling it with water and then examining it for leaks. This standard is important for ensuring that protective gloves do not allow harmful substances to reach the skin, thereby providing safety in chemical and biological environments.
EN 420:2003+A1:2009 is a European standard that sets out the general requirements for hand protection, including comfort, fit, and dexterity. Performance requirements include resistance to abrasion, cut, tear, puncture, and impact. Test results should show the gloves meet these requirements.
Jokasafe delivery terms
Free delivery when you order more than 500,00 € from Jokasafe
Supplier shipping fee 37,00 €
Brand minimum 0,00 €
JokaSafe JOK-NORD-1 JokaNordic Vinyl Protective Glove, 10 pairs
195,99 € / package (VAT incl.)
156,17 €
package VAT 0%
A package contains 10 pairs
15,62 € / pair
In a package
10 pairs
Jokasafe
Delivery time: 5 business days
Supplier shipping fee 37,00 €
Free shipping on orders over 500,00 €
Find +150,000 products from hundreds of brands
Autonomous sourcing platform
The most efficient way to source and order supplies for your operations
Sourcing
Ordering
Recommended products
List products you’re looking for and we’ll find the best products and prices for you – all for free.
We’ll help you find the right products and pricing for your business - all for free.
Product expert / ---